Details

Features of the TLV1226 Battery with F1 Terminals
 • Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance
   or water  adding.

 • Not restricted for air transport-complies with IATA/ICAO Special Provision A67.
 • UL-recognized component.
 • Can be mounted in any orientation.
 • Computer designed lead, calcium tin alloy grid for high power density.
 • Long service life, float or cyclic applications.
 • Maintenance-free operation.
 • Low self discharge.
 
Common Use & Applications:
 • UPS Standby Power Applications
 • Data Centers
 • Emergency 911 Centers
 • Hospitals & Medical Applications
 • Military Power Equipment
 • Emergency Lighting
 • Fire Detection and Alarm Devices
 
Product Specifications

 
Length 178mm (7.01 inch)
Width 35mm (1.38 inch)
Height 61mm (2.40 inch)
Total Height 67mm (2.64 inch)
Approx. Weight (kg / lbs) 0.99 (2.18)
   
Performance Characteristics

 
Nominal Voltage 12V
Number of Cells 6
Design Life 3~5 Years
Nominal Capacity 77°F(25°C)  
   20 hour rate (0.13A, 10.5V) 2.6Ah
   10 hour rate (0.258A, 10.5V) 2.58Ah
   5 hour rate (0.48A, 10.5V) 2.4Ah
   1 hour rate (1.95A, 9.6V) 1.95Ah
   
Internal Resistance  
   Fully charged battery 77°F( 25°C) 35mOhms
   
Self-Discharge 3% of capacity declined per month at 20°C (average)
Operating Temperature Range  
   Discharge -20~60°C
   Charge -10~60°C
   Storage -20~60°C

 
Max. Discharge Current 77°F(25°C)
39A (5s)
Short Circuit Current 130A
   
Charge Methods: Constant Voltage Charge 77°F(25°C)  
   Cycle Use 14.5-14.9V
      Maximum Charging Current 1.04A
      Temperature Compensation
-30mV/°C
   
Standby Use 13.6-13.8V
 
   Temperature Compensation -20mV/°C
   
 
Discharge Constant Current (Amperes at 77°F 25°C)
 
Discharge Constant Power (Watts at 77°F 25°C)

*(Note) The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values.
 
Discharge Characteristics(25℃)   Charging Characteristics(25℃)
 

Effect of Temperature on Capacity
 
Self-discharge Characteristics
 


Life characteristics of Standby Use
 
The Relationship for Charging Voltage and
Temperature
 

Floating Life on Temperature
 
Cycle Life on D.O.D(25℃)
 
 
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material  Lead dioxide  Lead  ABS ABS  Rubber  Copper  Fiberglass  Sulfuric acid 

 