Call Toll Free: 1-888-755-7718 sales@upsbatterycenter.com

12V 24Ah Sealed Lead Acid Battery (F4 Terminal)

12V 24Ah F4 TLV12240 Battery
High Performance
Brand New Fresh Stock
1 Year Warranty Included

Availability: In stock

$79.99

Shipping Information

  •   This item is in stock and ships within 1 business day
  •   We will gladly accept returns for any reason within 30 days of receipt of delivery
  •   Continental USA & Canada

Description

Details


Features of the TLV12240 - 12V 24Ah - F4 Battery
 
 • Absorbent Glass Mat (AGM) technology for premium performance
• Maintenance Free & Non-Spillable
• Operation in any orientation (upright, side, & end mounting recommended)
• Approved for transport by air. D.O.T., I.A.T.A., F.A.A., C.A.B.
• Classified as Non Hazardous, Non Dangerous Goods for Transportation
• Long service life in float or cyclic applications
• 5 Year Design Life at 25°C
• U.L. recognized under file number MH 49401
 
   
 Applications 
 • UPS Standby Power Applications
• Data Centers
• Emergency 911 Centers
• Hospitals & Medical Applications
• Military Power Equipment
• Emergency Lighting
• Fire Detection and Alarm Devices
 
   
 Dimensions and Weight 
 
Terminal:F4
Length (mm / inch)
166 / 6.54
Width (mm / inch)
175 / 6.89
Height (mm / inch)
125 / 4.92
Total Height (mm / inch)
125 / 4.92
Approx. Weight (kg / lbs)             8.1 / 17.8

 
 
  Discharge Constant Current (Amperes at 77°F 25°C)
End Point
Volts/Cell
5min10min15min30min1h3h5h10h20h
1.60V95.064.048.028.516.06.744.472.521.24
1.65V90.160.945.927.415.46.534.362.471.23
1.70V84.957.843.726.214.86.304.242.421.22
1.75V79.754.541.124.914.26.054.102.371.20
1.80V74.351.339.123.613.55.783.952.311.18
 
  Discharge Constant Power (Watts at 77°F 25°C)
End Point
Volts/Cell
5min10min15min30min45min1h2h3h5h
1.60V18512190.055.040.031.719.613.4 8.54
1.65V17311485.152.338.2 30.319.013.18.39
1.70V16110780.249.436.328.918.312.58.22
1.75V15199.775.246.634.327.517.612.08.03
1.80V13992.770.343.732.326.016.911.47.83
  (Note)The above characteristics data are average values obtained within
  three charge/discharge cycles not the mimimum values.
   
  Performance Characteristics 
 
   Nominal Voltage12V
   Number of cell6
   Design Life5 years
   Nominal Capacity 77°F(25°C) 
       20 hour rate (1.2A, 10.5V)24Ah
       10 hour rate (2.37A, 10.5V)23.7Ah
       5 hour rate (4.1A, 10.5V)20.5Ah
       1 hour rate (16A, 9.6V)16Ah
  
   Internal Resistance 
       Fully Charged battery 77°F(25°C)12mOhms
  
   Self-Discharge 
       Less than 3% discharge per month at 20°C(average) 
  
   Operating Temperature Range 
       Discharge-20~60ºC
       Charge
-10~60°C
       Storage
-20~60°C
  
   Max. Discharge Current 77°F(25°C)
300A(5s)
   Short Circuit Current
1200A
   Charge Methods: Constant Voltage Charge 77°F(25°C)
 
       Cycle use2.30-2.35VPC
            Maximum charging current9.6A
            Temperature compensation-30mV/°C
       Standby use2.23-2.27VPC
            Temperature compensation-20mV/°C
 
 
  Battery Construction
ComponentPositive PlateNegative PlateContainerCoverSafety ValveTerminalSeparatorElectrolyte
Raw MaterialLead DioxideLeadABSABSRubberCopperFiberglassSulfuric Acid
Contact us at sales@upsbatterycenter.com or call us Toll Free at 1-888-755-7718