6V 4.5Ah Sealed Lead Acid Battery

6V 4.5Ah TLV645 Battery
High Performance
Brand New Fresh Stock
1 Year Warranty Included

Availability: In stock

$14.99

Shipping Information

  •   This item is in stock and ships within 1 business day
  •   We will gladly accept returns for any reason within 30 days of receipt of delivery
  •   Continental USA & Canada

Description

Details


Features of the TLV645 - 6V 4.5Ah Battery
 
 • Absorbent Glass Mat (AGM) technology for premium performance
• Maintenance Free & Non-Spillable
• Operation in any orientation (upright, side, & end mounting recommended)
• Approved for transport by air. D.O.T., I.A.T.A., F.A.A., C.A.B.
• Classified as Non Hazardous, Non Dangerous Goods for Transportation
• Long service life in float or cyclic applications
• 5 Year Design Life at 25°C
• U.L. recognized under file number MH 49401
 
   
 Applications 
 • UPS Standby Power Applications
• Data Centers
• Emergency 911 Centers
• Hospitals & Medical Applications
• Military Power Equipment
• Emergency Lighting
• Fire Detection and Alarm Devices
 
   
 Dimensions and Weight 
 
Terminal:F1 (Faston .187)
Length (mm)70 / 2.76
Width (mm)47 / 1.85
Height (mm)101 / 3.98
Total Height (mm)107 / 4.21
Approx. Weight (kg / lbs)             0.77 / 1.70

 
 
  Discharge Constant Current (Amperes at 77°F 25°C)
End Point
Volts/Cell
5min10min15min30min1h3h5h10h20h
1.60V16.011.29.004.803.061.240.780.470.233
1.65V15.210.78.604.612.951.200.760.460.231
1.70V14.310.18.194.412.831.160.740.450.228
1.75V13.49.57.774.192.711.110.720.440.225
1.80V12.59.07.333.982.581.060.690.430.221
 
  Discharge Constant Power (Watts at 77°F 25°C)
End Point
Volts/Cell
5min10min15min30min45min1h2h3h5h
1.60V32.022.317.19.677.505.8003.412.46 1.59
1.65V30.021.016.39.187.14 5.563.312.401.56
1.70V28.019.715.58.696.785.3003.202.341.53
1.75V26.018.414.88.186.405.0503.082.271.50
1.80V24.117.113.87.686.004.7802.942.191.46
  (Note)The above characteristics data are average values obtained within
  three charge/discharge cycles not the mimimum values.
   
  Performance Characteristics 
 
   Nominal Voltage6V
   Number of cell3
   Design Life5 years
   Nominal Capacity 77°F(25°C) 
       20 hour rate (0.225A, 5.25V)4.5Ah
       10 hour rate (0.44A, 5.25V)4.4Ah
       5 hour rate (0.72A, 5.25V)3.6Ah
       1 hour rate (3.06A, 4.8V)3.06Ah
  
   Internal Resistance 
       Fully Charged battery 77°F(25°C)22mOhms
  
   Self-Discharge 
       Less than 3% discharge per month at 20°C(average) 
  
   Operating Temperature Range 
       Discharge-20~60ºC
       Charge
-10~60°C
       Storage
-20~60°C
  
   Max. Discharge Current 77°F(25°C)
67.5A(5s)
   Short Circuit Current
225A
   Charge Methods: Constant Voltage Charge 77°F(25°C) 
       Cycle use2.30-2.35VPC
            Maximum charging current1.8A
            Temperature compensation-15mV/°C
       Standby use2.23-2.27VPC
            Temperature compensation-10mV/°C
 
 
  Battery Construction
ComponentPositive PlateNegative PlateContainerCoverSafety ValveTerminalSeparatorElectrolyte
Raw MaterialLead DioxideLeadABSABSRubberCopperFiberglassSulfuric Acid
Contact us at sales@upsbatterycenter.com or call us Toll Free at 1-888-755-7718